Ir-Ta and Ru-Ir MMO coated titanium anodes for impressed current cathodic protection of long-distance pipelines, municipal pipeline networks and regional groundbeds.
Pipelines present distinctive ICCP challenges: long linear structures requiring uniform polarization, varying soil resistivity along the route, and (for seawater pipelines) mixed soil/electrolyte environments. No single anode structure covers all pipeline applications.
ANO offers three structure options, each with a distinct supply boundary: strip and wire anodes (A fully in-house), flexible groundbed anodes (A/B mixed: coating in-house, structural assembly external coordination), and deep well anodes (B overall external coordination for the deep-hole embedment).
All ANO-manufactured ICCP anode coatings (Ir-Ta for soil, Ru-Ir for seawater) are applied in-house on Grade 1 CP titanium substrates.
Standard Ir-Ta MMO coated titanium strip for soil-side pipeline protection and regional groundbeds.
| Parameter | Value / Description |
|---|---|
| Structure | Titanium strip, rolled in coils |
| Typical Dimensions | 535 mm × 0.635 mm (reference value) |
| Roll Length | 150–152 meters per standard roll (reference value) |
| Coating | Ir-Ta MMO — ANO proprietary formulation for soil environments (≤ 50 A/m², ≤ 40°C operating) |
| Supply Boundary | A · Fully in-house: coating, strip substrate, rolling, inspection — all ANO manufacturing |
| Typical Current Density | 50–110 mA/m² soil surface area (FHWA reference values) |
| Application | Long-distance pipeline soil-side ICCP, horizontal groundbeds, storage tank bottom supplementary groundbeds |
Ir-Ta/Ru-Ir MMO coated titanium wire for high-resistivity soil groundbeds and inline pipeline applications.
| Parameter | Value / Description |
|---|---|
| Structure | Titanium wire, straight cut or coiled to project length |
| Standard Diameters | Φ1.0 mm, Φ1.5 mm, Φ3.0 mm (reference values; ANO internal diameter tolerance confirmed per order) |
| Coating Options | Ir-Ta MMO for soil pipelines; Ru-Ir MMO for seawater pipelines (both ANO in-house) |
| Supply Boundary | A · Fully in-house: coating application on titanium wire substrate — ANO manufacturing |
| Application | High-resistivity soil groundbeds, vertical deep-hole wire installations (not the same as deep well anodes below), seawater pipeline external protection |
Note on wire specifications: Wire diameter tolerances, coating thickness and minimum bend radius for coiled wire are ANO proprietary manufacturing parameters. Reference values above represent industry-standard available sizes. Consult ANO for project-specific diameter confirmation.
Long-length flexible anodes for uniform polarization of large pipeline sections and high-resistivity soils.
Important: ANO can supply coated titanium wire only for flexible groundbed assemblies. The integrated flexible anode construction (Ti wire + copper lead + coke + braid) is assembled by external specialists. ANO does not represent the complete flexible anode system as an in-house product.
Deep-well ICCP groundbeds for very high-resistivity soils where conventional strip or wire groundbeds cannot achieve sufficient current output.
Deep well anodes require precision deep-hole embedment (≥ 15 m typical) with carefully engineered coke backfill and top-sealing. The deep-hole construction, coke packing, and top-plate sealing are specialized civil/ICCP engineering services supplied through external coordination.
ANO can supply the coated titanium core element (Ir-Ta or Ru-Ir MMO coated strip/wire) that goes into the deep well, but the complete deep well system — including drilling, coke installation and top cap — is coordinated through ANO's ICCP engineering partners.
| Your Application | Recommended Structure | Supply Boundary |
|---|---|---|
| Long-distance pipeline, moderate soil resistivity | ① Strip anode | A Fully in-house |
| High-resistivity soil groundbed | ② Wire anode | A Fully in-house |
| Large uniform polarization sections, flexible installation | ③ Flexible groundbed (coated wire from ANO) | A coating + B structure |
| Very high-resistivity soil, deep-hole requirement | ④ Deep well (coated core from ANO) | A core coating + B overall system |
| Seawater pipeline external protection | ② Wire anode with Ru-Ir MMO coating | A Fully in-house |
Detailed principles of ANO's Ir-Ta MMO (soil) and Ru-Ir MMO (seawater) coating systems, application environment selection, and thermal decomposition manufacturing. Read Technical →
Ru-Ir for full seawater, Ir-Ta for mud/soil interfaces — coating selection guide for ship hulls, steel piles and offshore platforms. Browse Product →
ANO supplies the coated titanium wire core. The full flexible groundbed anode (Ti wire + copper lead + coke + braid) is assembled by external specialists. ANO does not manufacture the complete flexible anode assembly.
The deep well drilling, coke backfill and top-plate sealing are specialized civil/ICCP engineering services. ANO can supply the coated titanium core element, but the complete deep well system is coordinated through ANO's ICCP engineering partners.
Ir-Ta MMO is used for soil and freshwater pipeline environments. Ru-Ir MMO is used for seawater pipelines and marine piles. Both coatings are proprietary ANO formulations applied in-house.
Reference standard diameters are Φ1.0 mm, Φ1.5 mm and Φ3.0 mm. ANO's specific internal diameter tolerances are confirmed per project. Non-standard diameters can be discussed during inquiry.
For strip, wire, coated-only flexible groundbed or coated-only deep well core requirements, please share: pipe diameter/length, soil resistivity measurements, whether the route crosses seawater, and your anode structure preference.
Send Inquiry
Ir-Ta MMO strip anodes for ground storage tank bottom cathodic protection.
Browse
Ir-Ta MMO expanded mesh anodes for bridges, parking structures and flood barriers.
Browse
Ru-Ir and Ir-Ta MMO anodes for ship hulls, steel piles and offshore platforms.
Browse
Ir-Ta vs Ru-Ir selection guide by environment — technical principles of ANO's two ICCP coating systems.
Browse