Ir-Ta MMO coated titanium strip anodes for impressed current cathodic protection of ground storage tank bottoms — soil-side corrosion prevention with 20+ year design life.
Ground storage tank bottoms suffer soil-side corrosion from moisture cycling, salt contamination, and varying soil chemistry. Traditional sacrificial anodes (Mg/Zn) require removal every 2–10 years. ICCP (impressed current cathodic protection) with Ir-Ta MMO anodes provides permanent corrosion control with 20+ year service life.
How it works: Ir-Ta MMO strip anodes are placed in the sand pad beneath the tank bottom. A DC power supply forces current from the anodes through the sand to the tank bottom steel, polarizing it to a protective potential (−0.85V to −1.10V vs. Cu/CuSO₄ reference). The MMO coating remains chemically inert in soil and groundwater environments.
ANO Supply Model: Complete Ir-Ta MMO strip anode — Grade 1 CP titanium substrate + in-house thermal decomposition Ir-Ta MMO coating + standard dimensions. All ANO in-house.
Ir-Ta mixed metal oxide by thermal decomposition — ANO proprietary formulation
Grade 1 CP titanium (ASTM B265) — corrosion-resistant base
535 mm × 0.635 mm strip thickness (reference values)
150–152 meters (standard roll length)
50–110 mA/m² (soil environment, reference values)
Soil / sand bed / groundwater — stable under resistivity 50–10,000 Ω·cm
Up to 40°C continuous service
>20 years application-level design; >75 years coating-level reference
Ir-Ta MMO is the industry standard coating for soil-side cathodic protection. Key advantages:
Reference values, non-ANO proprietary test data. Specific anode spacing, number of rolls and power supply sizing depend on tank dimensions, soil resistivity and design life.
Crude oil storage tanks, product tanks, LPG spheres — above-ground and underground.
Acid/caustic tanks with high chloride or salinity fill dirt.
Large-scale storage facilities with multiple tank bottoms requiring uniform polarization.
Cryogenic tank bottoms with specialized sand pad design.
Strip geometry provides high surface area-to-weight ratio, enables uniform current distribution across large tank bottom areas, and is easy to install in sand pads.
Typical design life >20 years. Accelerated coating life reference >75 years. Far superior to sacrificial Mg (2–5 years) or Zn (5–10 years).
Reliable in soil resistivity 50–10,000 Ω·cm. We advise on design for high-resistivity soils.
Yes — Ir-Ta MMO is fully manufactured in-house by ANO using our thermal decomposition coating line.
Please provide: tank diameter and height, product stored, soil resistivity data (if available), design life requirement, and new construction or retrofit.
Send Inquiry