ICCP CATHODIC PROTECTION / IR-TA MMO A · ANO FULLY IN-HOUSE

Storage Tank Bottom ICCP Anodes

Ir-Ta MMO coated titanium strip anodes for impressed current cathodic protection of ground storage tank bottoms — soil-side corrosion prevention with 20+ year design life.

Ground storage tank bottoms suffer soil-side corrosion from moisture cycling, salt contamination, and varying soil chemistry. Traditional sacrificial anodes (Mg/Zn) require removal every 2–10 years. ICCP (impressed current cathodic protection) with Ir-Ta MMO anodes provides permanent corrosion control with 20+ year service life.

How it works: Ir-Ta MMO strip anodes are placed in the sand pad beneath the tank bottom. A DC power supply forces current from the anodes through the sand to the tank bottom steel, polarizing it to a protective potential (−0.85V to −1.10V vs. Cu/CuSO₄ reference). The MMO coating remains chemically inert in soil and groundwater environments.

ANO Supply Model: Complete Ir-Ta MMO strip anode — Grade 1 CP titanium substrate + in-house thermal decomposition Ir-Ta MMO coating + standard dimensions. All ANO in-house.

Ir-Ta MMO Strip Anode Specifications

C

Coating

Ir-Ta mixed metal oxide by thermal decomposition — ANO proprietary formulation

S

Substrate

Grade 1 CP titanium (ASTM B265) — corrosion-resistant base

D

Dimensions

535 mm × 0.635 mm strip thickness (reference values)

L

Length per Roll

150–152 meters (standard roll length)

J

Typical Current Density

50–110 mA/m² (soil environment, reference values)

E

Environment

Soil / sand bed / groundwater — stable under resistivity 50–10,000 Ω·cm

T

Temperature

Up to 40°C continuous service

R

Service Life

>20 years application-level design; >75 years coating-level reference

Why Ir-Ta MMO for Tank Bottom ICCP?

Ir-Ta MMO is the industry standard coating for soil-side cathodic protection. Key advantages:

  • Chemical stability in soil. Resists hydrolysis and corrosion in neutral/acidic/alkaline soil conditions — Ru-based MMO is not suitable for soil service.
  • Long-term performance. Unlike Ru-based MMO which degrades above ~40°C or in low-Cl⁻ environments, Ir-Ta maintains stable performance for decades underground.
  • Uniform current distribution. Strip geometry ensures even current coverage across large tank bottom areas.
  • FHWA-recognized technology. Specified in FHWA (Federal Highway Administration) standards for cathodic protection.

Reference values, non-ANO proprietary test data. Specific anode spacing, number of rolls and power supply sizing depend on tank dimensions, soil resistivity and design life.

Applications & Industries

P

Petroleum Refineries

Crude oil storage tanks, product tanks, LPG spheres — above-ground and underground.

C

Chemical Storage

Acid/caustic tanks with high chloride or salinity fill dirt.

F

Fuel Depots

Large-scale storage facilities with multiple tank bottoms requiring uniform polarization.

L

LNG Storage

Cryogenic tank bottoms with specialized sand pad design.

Frequently Asked Questions

Why strip-shaped anodes?

Strip geometry provides high surface area-to-weight ratio, enables uniform current distribution across large tank bottom areas, and is easy to install in sand pads.

How long do Ir-Ta MMO anodes last?

Typical design life >20 years. Accelerated coating life reference >75 years. Far superior to sacrificial Mg (2–5 years) or Zn (5–10 years).

What soil conditions are suitable?

Reliable in soil resistivity 50–10,000 Ω·cm. We advise on design for high-resistivity soils.

Is Ir-Ta MMO manufactured by ANO?

Yes — Ir-Ta MMO is fully manufactured in-house by ANO using our thermal decomposition coating line.

Request a Quotation for Storage Tank Bottom ICCP Anodes

Please provide: tank diameter and height, product stored, soil resistivity data (if available), design life requirement, and new construction or retrofit.

Send Inquiry